  ?mounting method : ?liquid pressure : ?meter size and measurement range mounted via flange insertion type on oppo- site (wafer type) (with guide rings) ?2.5 to 200a note 1) guide ring : a ring-shaped guide used for centering the sensor when a wa- ter type is mounted on the piping. or flange mounting ?6 to 300a note 2) flange with meter size 2.5a or 6a can be used for 15a. -100 to 2000kpa or flange operating measuring range is equivalent to flow ve- locity 0.1 to 15m/s. sensor ?measurement item : ?structure : general-use industrial water, tap-water, sewage, waste water, chemicals slurry, and other liquids with conductivity of more than 3 s/cm. wafer type or flange type data sheet fma1, 2 integral type electromagnetic flowmeter features specifications note) meter size 2.5a: wafer type only 2.5a note 3) 0 to 0.00177 0 to 0.265 6a 0 to 0.0102 0 to 1.52 15a 0 to 0.0637 0 to 9.54 25a 0 to 0.177 0 to 26.5 40a 0 to 0.453 0 to 67.8 50a 0 to 0.707 0 to 106 80a 0 to 1.81 0 to 271 100a 0 to 2.83 0 to 424 150a 0 to 6.37 0 to 954 200a 0 to 11.3 0 to 1696 250a 0 to 17.7 0 to 2650 300a 0 to 25.5 0 to 3817 meter size min.measurement range [m 3 /h] max. measurement range [m 3 /h] the electromagnetic flowmeter is an instrument to measure the volumetric flow rate of liquid simply by applying a mag- netic field from the outside utilizing the fact that an electric conductor which crosses a magnetic field at a certain velocity causes voltage to be induced in proportion to the velocity, which is known as faraday? law. this flowmeter is designed with the latest electronics tech- nology and magnetic/electric field analyzing technology, real- izing a compact and light-weight structure and measurement with high accuracy. 1. high accuracy the adoption of the optimum magnetic field design using the 3-dimentional finite element method has minimized the effects of flow velocity profile and materials of adja- cent piping. at flow velocity of more than 1m/sfs,the measurement accuracy is as high as 0.5% of indicatedvalue when the flow is above 20%fs. 2. wide range measurement range: 0 to 0.1 ... 15m/sec in flow velocity 3. high-reliability structure the converter case is a sealed 2-chamber structure, practi- cally free from dew condensation and sudden submer- gence. the adoption of stainless housing assures excel- lent anti-environment efficiency. 4. easy-to-see display lcd with back-light allows easy check of display even in a dark place. instantaneous flow and integral volmetric flow are displayed at the same time. 5. free power supply the flowmeter operates on power supply 100 to 240v ac, 50/60 hz, eliminating the need for selection of power volt- age. 6. application of international standards the overall length of flange type flowmeter conforms with iso draft standards. (meter size : 6a-200a) date EDS6-69B oct. 29, 2001
2 fma1, 2 integration display : fault diagnosis turction : zero point adjustment : output low cut : integration low cut : 0% signal lock : slurry noise cut : empty detection : flow switch : dumping time constant : converter case : arrester : wiring connection port : painting : structure : grounding : integrated volumetric flow can be displayed by setting the unit of cubic volume. dis- played cubic volume; m 3 , l, ml various faults can be diagnosed by hard- ware check and process check. zero point is automatically calibrated with one-push operation. 0 to 10% fs momentary output can be cut to 0% at flow rate below the set cutoff point. 0 to 10% fs integration of display and output are pre- vented at flow rate below the set cutoff point. display and output can be locked to 0% with status input. 0 to 10% fs, 0 to 60 sec slurry noise (spike noise) can be cut by set- ting rate limit. absence of liquid is detected and status signal is outputted. ?0 to 110% fs status signal is outputted by setting high/ low limit flow. 1 to 200 sec aluminum alloy built-in power supply arrester and current output arrester g 1 /2 , npt 1 /2 , pg 13,5, m20 x 1,5 body case; polyurethane corrosion-resis- tant painting (silver) body cover; polyurethane corrosion-resis- tant painting (blue) jis c 0920 immersion-proof (ip67) d-class grounding (100 ? or less) conveter exciting system : input/output signal : pulse output : span setting : multi-range : flow direction change : flow display : square low-frequency exciting current output; 4 to 20ma dc load rasistance 0 to 1k ? pulse output; open-collector capacity; dc30v, 0.2a or less on voltage; 0.6v or less 0.0001 to 1000p/s status output; open-collector capacity: dc30v, 0.2a or less on voltage; 2v or less status input; no- voltage contact note) status signal input or output, either one, can be integrated pulses are outputted by setting integral constant. pulse width 0.5 to 80ms flow fs can be set by setting flow unit and flow value. flow velocity can also be set. display cubic volume, length; m 3 , l, ml, m display time unit ; /d, /h, /min, /s automatic 2-range selection in 2-range se- lect mode. external 2-range selection with status input is possible. flow direction can be reversed in flow di- rection mode. real time flow display, % display or user unit display is possible in 7 codes, max. ambient temperature-liquid temperature allowable range [ ? c] [ ? c] tefron lining polyurethane lining ambient tempertaure liquid temperature 120 80 50 -20 -10 20 50 60 material : note 1) materials of parts in contact with liquid should be selected in consideration of erosion due to measur- ing liquid. refer to the table of material selection on the attached sheet. note 2) flange type only sus304: unpainting carbon steel: polyurethane corrosion-resistant painting (silver) lining tefron(pfa, tfe) polyurethane electrode parts in contact with liquid note 1) sus316l hasteroy c titanium tantalum platinum iridium sus316l earth ring sus316 hasteroy c titanium tantalum sus316 housing case flange note 2) sus304 sus304 or carbon steel liquid temperature : ?0 to +120?c (tefron lining) ?0 to +50?c (polyurethane lining)
3 power consumption : operating condition : 12w or less ambient temperature; ?0 to 60?c (tefron lining sensor) ?0 to 50?c (urethane lining sensor) ambient humidity; 95% rh or less power voltage; 100 to 240v ac 10% power frequency; 50/60hz other specifications when replacing fuji' s former type sensors, flanges with short pipe are available. for details, contact our office. standard performance accuracy rating : meter size 2.5a to 15a 25a to 200a fs flow velocity 1m/s or more flow velocity 50%fs: 0.5% of rate flow velocity<50%fs: 0.25% fs fs flow velocity 0.3m/s or more less than 1m/s 0.5% fs _ flow velocity 50%fs: 0.5% of rate flow velocity<50%fs: 0.25% fs _ fs flow velocity 0.1m/s or more less than 0.3m/s (0.075/vs+0.25)% fs (vs:fs flow velocity [m/s]) flow velocity 50%fs: (0.075/vs+0.25)%f rate flow velocity<50%fs: (0.0375/vs+0.125)% fs _ flow velocity 20%fs: 0.5% of rate flow velocity<20%fs: 0.1% fs _
4 fma1, 2 length of straight pipe the length of the up-stream/down-stream straight pipe of the flowmeter should be long enough to ensure accurate measure- ments. see below. note 1) l=a multiple of diameter d of measuring pipe. note 2) do not put any objects, which affect magnetic field, electromotive force and flow profile, in the measuring pipe. note 3) use a straight pipe (2d to 3d) on the downsteam side, if the drift to the upstream side is affected by installing valves , etc. minimum length of straight pipe between upstream/downstream joints and flowmeter. note) "5d" with sluice valve fully open 1-1) upstream reducer pipe 1-2) upstream diffuser pipe 1-3) various upstream valves 1-4) upstream 90 bend 1-5) upstream t-pipe 2-1) downstream reducer pipe 2-2) downstream diffuser pipe 2-3) various downstream valves 2-4) downstream 90 bend 2-5) downstream t-pipe 5d flowing direction flowmeter flowing direction downstream straight pipe unnecessary downstream straight pipe unnecessary flowmeter 5d flowing direction flowmeter flowing direction flowmeter 10d note) flowing direction flowmeter 2 to 3d 2 to 3d 2 to 3d flowing direction flowmeter 5d flowing direction flowmeter flowing direction flowmeter 5d flowing direction flowing direction flowmeter flowmeter
5 mounting posture the flowmeter can be installed vertically, horizontally, or at other angle. when installing, be sure to observe the following points. q the measuring pipe should always fill with fluid which flows in the piping. example of mounting posture electrode mounting position (a) horizontal bypass line (b) vertical bypass line air are apt to form. fluid may not fill up the pipe. good good fluid may not fill up the pipe. pump e s c. e n t. i n c. shift e s c. e n t. i n c. shift e s c. e n t. i n c. shift e s c. e n t. i n c. shift e s c. e n t. i n c. shift &4$ &/5 */$ 4)*'5 ground < good > ground < good > ground < no good > electrode electrode w the electrode should be at a level with the ground and should always keep contact with fluid. (if the electrode is vertical to the ground air bubbles appear on the fluid and hence contaminated with deposits.) e use of a bypass valve will provide easy zero adjustment and maintenance. install a bypass line so that fluid flow is not interrupted. a bypass line installed as illustrated in the following figure (a) and (b) allows the inside of the pipe to be wa shed and cleaned without removing the flowmeter. e s c. e n t. i n c. shift e s c. e n t. i n c. shift bypass stop valve short pipe flow flowmeter flowmeter bypass stop valve flow short pipe coupling flange
6 fma1, 2 material measurable liquid unmeasurable liquid sus316 water and waste water, weak acid, weak alkali example: 25% acetic acid or less, hydroiodic acid, butyric acid, aqueous ammonia or alike inorganic acid, organic acid, chloride or alike hastelloy c-276 or equivalent suitable for intermediate oxidation and reduction and can be used for various fields. example: sea water, formic acid, acetic acid, aqueous ammonia, normal-temperature (lower than 40 c) nitric acid, hydrochloric acid and sulfuric acid or alike chloride, high-temperature strong acids (nitric acid, hydrochloric acid, sulfuric acid), high temperature (higher than 40 c) or high concentration (more than 40%) ferric chloride or alike titanium resistant to sea water, most oxidative acids, chloride, sulfide and alkali. example: sea water, saline water, aqueous ammonia, chlorine water, polyelectrolyte, acetic acid, ferric chloride or alike reductive acids such as hydrochloric acid, sulfuric acid, phosphoric acid, oxalic acid tantalum resistant to most chemicals. (particularly, strong acids) example: hydrochloric acid, sulfuric acid, nitric acid, aqua regia, ferric chloride, hypochlorous acid, sodium hypochlorite, pac (polyaluminum chloride) or alike sodium hydroxide, potassium hydroxide, hydroflouric acid, fuming sulfuric acid or alike platinum-iridium (pt-ir) resistant to almost chemicals. aqua regia material selection table the following table indicates examples of recommended materials, contacting with liquid, to be used with the typical liquids measured with electromagnetic flowmeter. evaluation of those materials has been conducted according to various documents and experience in actual use. material abrasion resistance heat resistance corrosion resistance adhesion resistance remarks teflon pfa teflon tfe poly-urethane ideal for the use with corrosive or adhesive fluids. not suitable for abrasive fluid (such as slurry.) pay attention to permeability of tfe. note that tfe is not suitable for use with high- temperature + negativepressure fluid. has inferior heat resistance or corrosion resistance. best for slurry or the like with no corrosive properties. [ : excellent, : very good, : good, : no good] 1. characteristics of lining materials 2. material selection table of electrode/earth ring
7 code symbols description meter size (5th code) 2.5a 6a 15a 25a 40a 50a 80a 100a 150a 200a s a c d t e f g h j p u lining material (6th code) pfa mold tefron polyurethane rubber (7th & 9th code; w only) note) polyurethane rubber with less than 15a of meter size cannot be used. 14 1 10 ma f-- 12345678 101112 913 electrode material (9th code) sus316l hasteroy c titanium tantalum platinum iridium w h c t p guide ring (11th code) for jis 10k for jis 20k for jis 75m (meter size of less than 50a cannot be used) for ansi 150lb for ansi 300lb for din/pn 16k for din/pn 40k 1 2 7 5 6 8 9 wiring connection port size (12th code) g 1 /2 female screw g 1 /2 (pf 1 /2 ) female screw with water-proof gland g 1 /2 (pf 1 /2 ) female screw with union and water-proof gland npt 1 /2 female screw pg 13.5 female screw m20 1.5 female screw y a b c d e optional specifications (14th code) none stainless tag plate parameter setting parameter setting and stainless tag plate note) when parameter setting function is used, specify parameters in parameter designation tables 1 and 2. y a b c direction of indicator (13th code) see fig 1 horizontal mounting vertical mounting 1 2 flange (10th code) none 0 earth ring material (7th code) sus316 hasteroy c titanium tantalum w h c t integral type electromagnetic flowmeter (wafer type) fig 1 direction of indicator horizontal mounting (code 1) vertical mounting (code 2) upper lower esc. ent. inc. shift contrast esc. ent. inc. shift contrast
8 fma1, 2 inside diameter (5th code) 6a note 15a 25a 40a 50a 80a 100a 150a 200a 250a 300a note) flange size for meter size 6a is 15a or 1 /2 b. a c d t e f g h j k l p t u lining material (6th code) pfa mold tefron note 1 tfe tefron note 2 polyurethane rubber note 3 (7th & 9th codes: w only) note 1) pfa 6a to 200a note 2) tfe 250a, 300a note 3) polyurethane rubber with less than 15a of meter size cannot be used. 14 1 20 ma f-- 12345678 101112 913 electrode material (9th code) sus316l hasteroy c titanium tantalum platinum iridium w h c t p guide ring (11th code) none 0 wiring connection port size (12th code) g 1 /2 female screw g 1 /2 (pf 1 /2 ) female screw with water-proof gland g 1 /2 (pf 1 /2 ) female screw with union and water-proof gland npt 1 /2 female screw pg 13.5 female screw m20 1.5 female screw y a b c d e optional specifications (14th code) none stainless tag plate parameter setting parameter setting and stainless tag plate y a b c direction of indicator (13th code) see fig.1 horizontal mounting vertical mounting 1 2 flange standard flange material (10th code) jis 10k sus304 jis 20k sus304 jis 75m sus304 note 2 ansi 150lb sus304 ansi 300lb sus304 din pn16 sus304 din pn40 sus304 note 1 jis 10k carbon steel jis 20k carbon steel note 3 jis 75m carbon steel note 2 ansi 150lb carbon steel ansi 300lb carbon steel din pn16 carbon steel din pn40 carbon steel note1 note 1) meter size 100a or more cannot be used. note 2) meter size 50a or less cannot be used. note 3) meter size 250a or 300a can be selected only for a, b and d. 1 2 4 5 6 7 8 a b d e f g h earth ring material (7th code) sus316 hasteroy c titanium tantalum w h c t integral type electromagnetic flowmeter (flange type) description note) when parameter setting function is used, specify parameters in parameter designation tables 1 and 2.
9 meter size mass (kg) 2.5a 6a 15a 25a 40a 50a 80a 100a 150a 200a 85 85 85 93 100 105 150 160 190 205 2.5 6 12 22.6 35.6 47.8 72.3 97.6 150 200 50 50 50 68 86 96 125 160 211 271 226 w d dh 226 226 244 262 272 301 346 397 457 4 4 4 4.5 5.5 6 9.5 12 16.5 26.5 *3 *1 *1 with water-proof gland *2 with union and water-proof gland *3 for vertical mounting type, it is mounted with the indicator turned clockwise by 90. *2 135 222 w 20 (stainless tag) option note) when earth ring material is tantalum, w is shortened by 4mm. detail of "a" d m 15 75 h d l1 l2 ml1 l2 g 1 /2 npt 1 /2 pg13.5 m20 1.5 13.5 16 10.5 16 18.5 21 15 21 wiring lead-in port a outline diagram (unit: mm) (wafer type sensor)
10 fma1, 2 meter size 6a 15a 25a 40a 50a 80a 100a 150a 200a 200 200 200 200 200 200 250 300 350 206 206 206 206 206 206 256 306 356 95 95 125 140 155 185 210 280 330 70 70 90 105 120 150 175 240 290 4-15 4-15 4-19 4-19 4-19 8-19 8-19 8-23 12-23 12 12 14 16 16 18 18 22 22 46 46 66 82 92 121 152 202 260 6 12 22.6 35.6 47.8 72.3 97.6 150 200 248 248 272 289 301 331 371 431 486 102 112 144 171 5.5 5.5 7.5 9.5 10.5 16.5 20.5 37.5 51 w1 w2 jis 10k flange note 1 : for inside diameter 6a, use flange jis 15a. 20 (stainless tag) option 75 *3 eye-bolt, meter size 80a or more n- b inside diameter 80a or more w1 t w2 135 g d d c f h 222 *1 *1 with water-proof gland *2 with union and water-proof gland *3 for vertical mounting type, it is mounted with the indicator turned clockwise by 90. *2 note) when earth ring material is tantalum, w is shortened by 4mm. 0 3 +1 3 211 238 290 342 168 195 247 299 4-19 4-19 6-19 8-19 18 18 22 22 121 152 202 260 72.3 97.6 150 200 344 385 436 492 113 124 163 176 19 23.5 36.5 54 d c n- b t g d h f d c n- b t g d h f jis 75m flange 95 95 125 140 155 200 225 305 350 70 70 90 105 120 160 185 260 305 4-15 4-15 4-19 4-19 8-19 8-23 8-23 12-25 12-25 14 14 16 18 18 22 24 28 30 46 46 66 82 92 121 152 202 260 6 12 22.6 35.6 47.8 72.3 97.6 150 200 248 248 272 28.9 301 339 379 444 496 108 118 160 179 5.5 5.5 8 10 10.5 18.5 23.5 41 59.5 jis 20k flange mass (kg) d c n- b t g d h f mass (kg) mass (kg) ml1 l2 g 1 / 2 npt 1 / 2 pg13.5 m20 1.5 13.5 16 10.5 16 18.5 21 15 21 detail of "a" m 15 l1 l2 wiring lead-in port a (note1) outline diagram (unit: mm) (flange type sensor)
11 w1 meter size 6a (note3) 15a 25a 40a 50a 80a 100a 150a 200a 6 6 7.5 10.5 12 19.5 d c n- b t d f d c n- b t d f 200 200 200 200 200 200 250 300 350 95 95 115 150 165 200 65 65 85 110 125 160 4-14 4-14 4-14 4-18 4-18 8-18 16 16 18 18 20 24 6 12 22.6 35.6 47.8 72.3 248 248 267 294 306 108 95 95 115 150 165 200 220 285 340 65 65 85 110 125 160 180 240 295 4-14 4-14 4-14 4-18 4-18 8-18 8-18 8-22 12-22 16 16 18 18 20 20 20 22 24 6 12 22.6 35.6 47.8 72.3 97.6 150 200 108 116 151 175 6 6 8 10.5 12 18.5 22 35 54 h 338 h 248 248 267 274 306 339 376 434 472 w2 206 206 206 206 206 206 256 306 356 g din pn16 flange din pn40 flange 46 46 66 82 92 121 152 202 260 g 121 46 46 66 82 92 w1 meter size 1 /4 b (note2) 1 /2 b1b1 1 /2 b2b 3b 4b 6b 8b 5.5 5.5 8 11.5 12 22 32 50.5 78.5 d c n- b t d f mass (kg) mass (kg) mass (kg) mass (kg) d c n- b t d f 200 200 200 200 200 200 250 300 350 95 95 124 156 165 210 254 318 381 66.7 66.7 88.9 114.3 127 168.3 200 269.9 330.2 4-16 4-16 4-20 4-23 8-20 8-23 8-23 12-23 12-26 14.5 14.5 17.5 21 22.5 29 32 37 41.5 6 12 22.6 35.6 47.8 72.3 97.6 150 200 248 248 272 297 306 112 130 165 193 89 89 108 127 152 191 229 279 343 60.3 60.3 79.4 98.4 120.6 152.4 190.5 241.3 298.4 4-16 4-16 4-16 4-16 4-20 4-20 8-20 8-23 8-23 11.5 11.5 14.5 17.5 19.5 24 24 25.5 29 6 12 22.6 35.6 47.8 72.3 97.6 150 200 104 120 144 176 5 5 7 9 11 19 24.5 35.5 58.5 h 343 393 450 512 h 245 245 264 282 300 334 380 431 493 w2 206 206 206 206 206 206 256 306 356 g ansi 150lb flange ansi 300lb flange 46 46 66 82 92 121 152 202 260 g 121 152 202 260 46 46 66 82 92 note 3 : for meter size 6a, use flange din 15a. note 2 : for meter size 1 /4 b, use flange ansi 1 /2 b.
12 fma1, 2 l2 21 15 18.5 m pg13.5 g 1 /2 npt 1 /2 13.5 10.5 16 l1 m20 1.5 16 21 flange *3 48 120 430 380 46 d t c n- b 12-27 100 480 430 16-27 38 115 410 360 36 d t n- b c 8-23 97 10-23 414 464 300a 360 595 598 445 250 400 38 16-25 115 220 543 h h1 97 *1 *2 320 w1 36 12-25 355 400 595 t n- b c d 250a w d t w 3 w1 h1 n- b c h 222 135 20 (stainless tag) option 75 detail of "a" m 15 l1 l2 meter size jis 10k flange jis 20k flange jis 75m flange mass (kg) mass (kg) mass (kg) eye-bolt *1 with water-proof gland *2 with union and water-proof gland *3 for vertical mounting type, it is mounted with the indicator turned clockwise by 90. wiring lead-in port a outline diagram (unit: mm)
13 n o o + l pls + pls st + st + power supply current output status input / output integrated pulse output 15.0 10.0 5.0 1.0 0.5 0.1 0.01 0.05 0.1 0.05 1 0.5 10 5 100 50 1000 500 4000 flow rate [m 3 / h] flow velocity [m/ s] 2.5a 6a 15a 25a 40a 50a 80a 100a 150a 200a 250a 300a external connection diagram flow rate-flow velocity conversion diagram scope of delivery main unit (mounting bolt and packing should be prepared separately) spare parts (spare fuse (1a), guide rings / for wafer type (note), 1set spare water-proof gland / for water-proof gland type) note) not supplied for 2.5a-25a ansi 150lb and 100a, 200a jis 10k. items specified at ordering 1. type, specification code 2. flow measurement range and mesurement fluid. 3. stainless tag plate, and tag no. (less than 16 alphanumeric characters). 4. if you want the instrument with certain parameters factory set as you desire, submit the parameter designation tables 1 and 2 when specifying them.
14 fma1, 2 if you want the instrument with certain parameters factory set as you desire, specify them in parameter designation tables 1 an d 2. put check marks into which precede items to modify for. setting item standard set value (note 1) range item to select item selection or value designation example damping 3.0s 1.0 to 200.0s ? ? ?}? [s] 020.0s company : name : measured fluid : sector : telephone no. : 1st range instantaneous output low-cut point current output burnout integration direction integration con- stant (note 2) (integration value per pulse) integrated pulse width (note 3) integration preset value range designated at order placing 0.0 ? under scale (2.4ma) forward 0m3 30ms 0m3 0.1 to 15 m/s converted to flow velocity. 0.0% to 10.0% not used (hold) over scale (21.6ma) under scale (2.4ma) forward reverse value: 0.000000000 to 9999999999. unit : ml, l, m 3 0.5 to 80ms value: 9999999999 to +9999999999 unit : linked with unit of integration constant. volume unit : ? ml, ? l, ? m 3 time unit: ? /s, ? /min, yyyyy? /h, ? /d none. ? not used ? over scale ? under scale ? forward ? reverse volume unit: ? ml, ? l, ? m 3 none. none. must be designated in 4 significant digits. value: ? ? ? ? ? ? ? . ?? none. none. value: ? ? ? ? ? ? ? ? ? ? ? ? . ? [ms] ? ? ? ? ? ? ? ? ? ? 100.0 3.5% 50.0[ms] 100000 lcd 1st line indication lcd 2nd line indication real scale indication unit: factory set as per range designation percent indication <1st line, 2nd line> q flow velocity indication (m/s) w real scale volume unit: ml, l, m 3 time unit: /s, /min, /h, /d e percent indication (%) r arbitrary unit indication user factor: 0.0001 to 99999. user unit: up to six ascii code characters. must be designated for mass flow rate indication, etc. if mass flow rate indication (*) is designated, designate the density of measured fluid instead of user factor. t integrated real scale indication volume unit: ml, l, m 3 y integrated pulse indication separately designate the integration constant together. u integration arbitrary unit indication user factor: 0.0001 to 99999. user unit: up to four ascii code characters. must be designated for mass flow rate indication, etc. if mass indication (*) is designated, designate the density of measured fluid instead of user factor. i status i/o indication indication of function and action of status i/o selected on 2nd line of lcd (can specify 2nd line only). o no function do not indicate lcd 2nd line (can specify 2nd line only). (*): electromagnetic flow meter is a volumetric flow meter. in case of mass or mass flow rate indication, therefore, any change of density of measured fluid causes an error. select an item from the following. ? flow velocity indication ? real scale indication ? percent indication ? arbitrary unit indication ? integrated real scale indication ? integrated pulse indication ? integration arbitrary unit y indication select an item from the following. ? flow velocity indication ? real scale indication ? percent indication ? arbitrary unit indication ? integrated real scale indication ? integrated pulse indication ? integration arbitrary unit y indication ? status i/o indication ? no function according to selection of left item, designate necessary item and value. unit: m/s fixed. volume unit: ? ml, ? l, ? m 3 time unit: ? /s, ? /min, ? /h, ? /d none. user factor: ? ? ? ? ? ? or, for mass flow rate indication, designate the density of measured fluid instead of user factor. density of fluid: ? ? ? ? ? user unit: ? ? ? ? ? ? volume unit: ? ml, ? l, ? m 3 * designate integration constant separately. user factor: ? ? ? ? ? ? or, for mass flow rate indication, designate the density of measured fluid instead of user factor. density of fluid: ? ? ? ? ? user unit: ? ? ? ? ? ? according to selection of left item, designate necessary item and value. unit: m/s fixed. volume unit: ? ml, ? l, ? m 3 time unit: ? /s, ? /min, ? /h, ? /d none. user factor: ? ? ? ? ? ? or, for mass flow rate indication, designate the density of measured fluid instead of user factor. density of fluid: ? ? ? ? ? user unit: ? ? ? ? ? ? volume unit: ? ml, ? l, ? m 3 * designate integration constant separately. user factor: ? ? ? ? ? ? or, for mass flow rate indication, designate the density of measured fluid instead of user factor. density of fluid: ? ? ? ? ? user unit: ? ? ? ? ? ? none. none. 0.9765 t/h 0.9765 t 0.9765 t/h 0.9765 t (note 1) standard set value refers to parameter set value as factory set in case parameter setting is not designated. (note 2) designate so that 0.0001 to 1000 pulses integrated will be output per second (so that following expression will hold) w hen flow rate is maximum. 0.0001 ? range [m 3 /h] / (integration constant [m 3 ] 3600) ? 1000 (note 3) designate the integrated pulse width so as to hold: (integration constant [m 3 ]) 3600/range [m 3 /h] ? integrated pulse width [ms]/500
15 integration low-cut point integration burnout status function empty detection function tag-no flow direction 3.0% hold no function inhibit blank unless designated forward 0.0 to 10.0% hold count q no function w external 2 range changeover 2nd range: 0.1 to 15 m/s converted to flow velocity. status input: input closed (note 4) input open e external forward/reverse range changeover 2nd range: 0.1 to 15 m/s converted to flow velocity. status input: input closed (note 4) input open r 0% signal lock status input: input closed (note 4) input open t external zero adjustment status input: input closed (note 4) input open y external integration preset status input: input closed (note 4) input open * designate preset value separately in item of integration preset value . u automatic 2 range changeover 2nd range: 0.1 to 15 m/s converted to flow velocity. changeover hysteresis: 0.0 to 20.0% (with respect to smaller range). status output: output on (note 5) output off i automatic forward/reverse changeover 2nd range: 0.1 to 15 m/s converted to flow velocity. changeover hysteresis: 0.0 to 10.0% (with respect to smaller range). status output: output on (note 5) output off o flow switch upper limit: -10.0 to 110.1% (if 110.1% is selected, upper limit is invalid). lower limit: -10.1 to 110.0% (if -10.1% is selected, lower limit is invalid). status output: output on (note 5) output off ! 0 integration switch set value: 9999999999 to +9999999999 status output: output on (note 5) output off * unit is the same as set value for integration constant. ! 1 alarm output alarm selection all function, hardware fault, process fault status output: output on (note 5) output off inhibit enable up to 16 alphanumerics forward reverse none ? hold ? count select one of functions below. ? no function ? external 2 range changeover ? external forward/reverse range changeover ? 0% signal lock ? external zero adjustment ? external integration preset ? automatic 2 range changeover ? automatic forward/reverse changeover ? flow switch ? integration switch ? alarm output ? inhibit ? enable none ? forward ? reverse ? ?}? [%] none according to selection on the left, designate item and value. none must be designated in 4 significant digits. 2nd range: ? ? ? ? volume unit: ? ml, ? l, ? m 3 time unit: ? /s, ? /min, ? /h, ? /d ? input closed ? input open must be designated in 4 significant digits. 2nd range: ? ? ? ? volume unit: ? ml, ? l, ? m 3 time unit: ? /s, ? /min, ? /h, ? /d ? input closed ? input open ? input closed ? input open ? input closed ? input open ? input closed ? input open must be designated in 4 significant digits. 2nd range: ? ? ? ? volume unit: ? ml, ? l, ? m 3 time unit: ? /s, ? /min, ? /h, ? /d hysteresis: ? ? . ? ? ? output on ? output off must be designated in 4 significant digits. 2nd range: ? ? ? ? volume unit: ? ml, ? l, ? m 3 time unit: ? /s, ? /min, ? /h, ? /d hysteresis: ? ? . ? ? ? output on ? output off upper limit: ? ? ? . ? [%] lower limit: ? ? ? . ? [%] ? output on ? output off set value: ? ? ? ? ? ? ? ? ? ? ? ? output on ? output off alarm selection ? all function ? hardware fault ? process fault status output: ? output on ? output off none ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? none 5.0% 10.00 10.00 10.00 5.0% 10.00 5.0% +90.0[%] 02.0[%] f-100 (note 4) status input specifications: no-voltage contact. 1 k ? or less when closed. 50 k ? or more when open. (note 5) status output specifications: capacity; 30v dc or less, 0.2a or less, on voltage; 2v or less setting item standard set value (note 1) range item to select item selection or value designation example
fma1, 2 information in this catalog is subject to change without notice. printed in japan head office gate city ohsaki, east tower, 11-2, osaki 1-chome, shinagawa-ku, tokyo 141-0032, japan http://www.fesys.co.jp/eng instrumentation div. international sales dept. no.1, fuji-machi, hino-city, tokyo, 191-8502 japan phone: 81-42-585-6201, 6202 fax: 81-42-585-6187 http://www.fic-net.jp/eng caution on safety *before using this product, be sure to read its instruction manual in advance.


▲Up To Search▲   

 
Price & Availability of EDS6-69B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X